MG-S series operation manual 1
Prior to use
-
3
-
1-2
For more accurate measurement
To make more accurate measurement, it is necessary to lessen error-causing factors in measurement
to the extent possible. Error-causing factors include not only an instrument error and performance of
the balance itself but also the nature and condition of a specimen, measuring environment (vibration,
temperature, humidity, etc.) and the like. These factors will directly affect measurement result in the
case of a balance with high resolution capability.
1-2-1
Precautions related to measuring environment
Temperature/
humidity/
atmospheric
pressure
→
Try to keep the room temperature constant to the extent possible in order to
avoid condensation and indication drift due to change in temperature.
→
Low humidity is likely to cause generation of static electricity, resulting in
inaccurate measurement.
Vibration/shaking
→
It is preferable to locate a measuring room on the first floor or the basement. The
higher the room is, the larger the vibration and shaking become. Therefore, a
highly located room is not suitable for measurement. Rooms near the railway or
road side should also be avoided.
Air draft
→
Places directly exposed to air current from an air-conditioner or to direct sun
generate abrupt temperature change and resultantly cause unstable weight
indication, and therefore, should be avoided.
Gravity
→
The latitude and altitude of a measuring location differentiate the gravity that
affects a specimen, giving a different weight indication to the same specimen.
Electromagnetic
wave
→
At a location where a strong electromagnetic wave generating object is in the
proximity of a balance, the balance is affected by the electromagnetic wave,
making the balance unable to indicate accurate weight, and therefore, such a
location should be avoided.
1-2-2
Precautions related to measuring table
Vibration/shaking
→
Vibrations during measurement destabilizes the indication of measurement
value, leading to inability to make accurate measurement. And so use of a
measurement table that is robust and hardly affected by vibration is required (a
vibration-proof structured table or concrete or stone-made table is suitable). In
addition, placing a sheet of soft cloth or paper under the balance causes shaking
or makes keeping horizontal attitude difficult, and therefore should be avoided.
→
The measurement table should be installed in a position free from vibration to
the extent possible. A corner rather than the center of a room is less affected by
vibration and therefore more suitable for installation of the balance.
Magnetism/Static
electricity
→
Use of the balance on the table that is subject to magnetism or static electricity
should be avoided.
Содержание MG-S Series
Страница 2: ......
Страница 10: ......
Страница 67: ...MG S series operation manual 6 External input output functions 57 ...
Страница 68: ...6 External input output functions MG S series operation manual 58 ...
Страница 84: ...8 Controlling and adjustment functions MG S series operation manual 74 ...
Страница 103: ...MG S series operation manual Appendix 93 Appendix 2 Dimensional outline drawing MG S322 MG S1501 MG S8200 ...
Страница 109: ...MG S series operation manual Appendix 99 Appendix 7 Windshield assembly instructions ...
Страница 110: ...Appendix MG S series operation manual 100 ...
Страница 111: ...MG S series operation manual Appendix 101 ...
Страница 113: ......
Страница 114: ......