1
Prior to use MG-S series operation manual
-
2
-
■
Do not mix old and new batteries, or batteries of different types or manufacturers.
■
Do not use the batteries that leak.
■
Do not apply excessive force to or impact the balance.
Doing so could damage or result in failure of the balance. Carefully place samples on the balance.
■
Do not use volatile solvents.
The main unit could deform. Wipe the main unit using dry cloth or a cloth moistened with a small
amount of neutral detergent.
■
Dispose of batteries in accordance with local regulations.
■
If the balance is not going to be used for a long time, store it with the batteries
removed.
■
Observe the precautions printed on the batteries used.
FCC
caution
■
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
■
Do not install the balance in a place where it is directly exposed to airflow from air-
conditioning or heating equipment.
Due to changes in the ambient temperature, the balance could fail to accurately weigh samples.
■
Do not install the balance in a place exposed to direct sunlight.
The internal temperature of the balance could rise and the balance could fail to accurately weigh
samples.
■
Do not install the balance where the floor is soft.
When a sample is placed on the balance, the balance could slant and fail to accurately weigh samples.
■
Do not install the balance in a place where the ambient temperature or humidity
change significantly
.
The balance could fail to accurately weigh samples.
■
Adjust (calibrate) the balance when it is installed or relocated.
Failure to do so might result in measurement errors. To ensure accurate measurements be sure to
adjust (calibrate) the balance.
■
Check for an error periodically.
Use environment and chronological change cause an error in measured value, leading to an inaccurate
measurement.
■
Unplug the AC adapter from the receptacle when the balance is not going to be
used for a long period of time.
Unplug the balance from the receptacle to save energy and prevent degradation.
■
Always adjust the level of the balance before use.
A tilted balance generates errors which might cause inaccurate weighting.
■For proper disposal
This product including accessories may not be disposed of in domestic waste in conformance with
the specific requirements in your country or state.
When you dispose of this product, please contact your local authorities or dealer and ask for the correct
method of disposal.
FCC
Note
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This product contains unlicensed transmitting module:
- Name: Stand-alone dual-mode Bluetooth module OBS421 series
- Model number: CB-OBS421i-i4-01B
- FCC ID: PVH0946
Содержание MG-S Series
Страница 2: ......
Страница 10: ......
Страница 67: ...MG S series operation manual 6 External input output functions 57 ...
Страница 68: ...6 External input output functions MG S series operation manual 58 ...
Страница 84: ...8 Controlling and adjustment functions MG S series operation manual 74 ...
Страница 103: ...MG S series operation manual Appendix 93 Appendix 2 Dimensional outline drawing MG S322 MG S1501 MG S8200 ...
Страница 109: ...MG S series operation manual Appendix 99 Appendix 7 Windshield assembly instructions ...
Страница 110: ...Appendix MG S series operation manual 100 ...
Страница 111: ...MG S series operation manual Appendix 101 ...
Страница 113: ......