Status Code
Description
Remediation IF Necessary
00
Normal operation—All OK
20
Breakout
33
System error
See attachment 7
34
Internal communication error – Type 1
See attachment 7
35
Motor drive failure
Replace controller
36
Internal communication error – Type 2
See attachment 7
0b
Obstruction
A0
First Installation Sequence (FIS)
A1
Auto-configuration sequence
A2
Auto-configuration confirmation sequence
b1
Encoder error > cable failure
Verify magnet/encoder pair
b2
Encoder mismatch > wrong encoder/magnet
Verify magnet/encoder pair
b3
Encoder fault > wrong encoder/magnet or
cable falure
Verify magnet/encoder pair
bE
Blocked egress
c1
Position learn error
Ld
Lock down (shear lock energized)
db
Output control
See Attachment 6, Sheet 2 of 2
dc
Display door cycle counter
dE
Delayed egress
d0
Free egress
E2
Door held open by any sensor input other than
the Hold Open switch on TB2-1.
E3
Door length error
Re-do First Installation Sequence (FIS)
E4
Presence sensor monitoring failure
Verify sensor wiring and safety logic setting
E5
Motor drive failure
F0
Inside monitored sensor failure
Verify sensor wiring and safety logic setting
F1
Outside monitored sensor failure
Verify sensor wiring and safety logic setting
F2
Upper Monitored Photo Beam failure
Check transmitter, receiver, and hold beam type
F3
Lower Monitored Photo Beam failure
Check transmitter, receiver, and hold beam type
F6
Inside (2) monitored sensor failure
Verify sensor wiring and safety logic setting
F7
Outside (2) monitored sensor failure
Verify sensor wiring and safety logic setting
ho
Door held open
Check sensors and hold beam type
FA
Fire Alarm Active
uL
Unlocked delay egress