Index
Min
Value
Max
Value
Description
Defaults
Single
Dual
31
1
99* Close Learn
Speed
Close Learn Speed is the speed used on power up,
during FIS and after an obstruction. The controller
display may indicate either 07 or 09 as a door state
and still use Close Learn Speed based on the
conditions listed prior.
This speed is typically set higher than check speed,
to allow faster door motion when not in the check
zones, but still slower door motion than normal
operation.
This parameter sets the target speed setting. Other
parameters like close learn torque and close
acceleration as well as door properties like friction,
door length, and door weight affect door speed.
20
20
32
1
99
Close Learn
Torque
Close Learn Torque is the torque used on power up,
during FIS, after an obstruction.
This torque must be set to comply with ANSI/
BHMA door force requirements.
This parameter sets the maximum current available
to the motor which is directly proportional to the
door force. This torque setting is used in
conjunction with Close Learn Speed.
30
25
33
0
99
Close Startup
Length
Close Startup Length is the percent of door length
in which Close Startup Torque parameter is used.
These parameters are used to overcome friction
encountered at the begining of close door motion.
This parameter should be set as low as possible to
ensure reliable operation.
0
0
35
1
99
Close Startup
Torque
Close Startup Torque is the torque used when
entering the closing state (07). It is used for a
configurable door length (determined by the Close
Startup Length parameter). After this door length,
the torque setting will revert to the Close Torque.
This torque should be set greater than Close Torque
to ensure that the controller can start door motion,
overcome static friction, and avoid obstructions.
This torque must be set to comply with ANSI/BHMA
door force requirements.
This parameter sets the maximum current available
to the motor which is directly proportional to the
door force.
35
25
Table 3. Settings (continued)
Table 3 Settings continued next page.