iQ Control Box
18 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C.
All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
01.25.2019
Table 5. Door States
Door State
Description
00
Door State is Closed
02
Door State is Opening
04
Door State is in Open Check
06
Door State is Full Open
07
Door State is Closing
09
Door State is in Close Check
10
Open Assist (manual mode door state)
11
Close Assist (manual mode door state)
12
Close Assist (manual mode door state)
14
Door Fault
15
Door State is in Open Stop
16
Door State is in Obstruction while Closing
17
Door State is in Close Press
19
Lock Release (door state)
NOTE
: If the current status code is “Normal operation—All OK”, the iQ will show the current door state.
Otherwise, the iQ alternates between showing the current status code and the door state.
Final Tune-In Adjustments
1. Refer to ANSI/BHMA A156.10, “Standard for Power Operated Pedestrian Doors,” and attachment 4 and
DETERMINE ANSI and UL door operating requirements.
2. IF Stanguard
TM
threshold sensor is installed, refer to Stanley Access Technologies document No. 203768,
“Stanguard
TM
Threshold Sensor Installation and Operation,” and TUNE-IN Stanguard
TM
threshold sensor.
Ensure that the JP301 Jumper is properly installed for StanGuard
TM
Sensors.
3. IF SU-100 motion sensor(s) are installed, refer to Stanley Access Technologies document No. 203957,
“SU-100 Motion Sensor Installation and Operation,” and TUNE-IN SU-100 motion sensor(s).
4. IF Optex X Zone T or X Zone ST Sensors are installed, refer to the manufacturer’s installation and tune-in instructions.
5. If Hotron HR100 ST sensors are installed, refer to the manufacturer’s instructions.
6. After all changes have been made, cycle the door to have the settings stored in Non-Volatile memory.
Then turn power OFF and then back ON to ensure that all of the settings are permanently stored.
• Verify that the correct Safety Logic has been selected for Sensor Monitoring and that the JP301 is in the
correct position.
• DO NOT remove JP301 when Stanguard™ is installed. X Zone T, X Zone ST and HR100 ST monitored sensors
require JP301 to be removed.
7. This step only applies to the Stanley Automatic ICU series doors: Refer to ANSI/BHMA A156.38, “American
National Standard for Low Energy Power Operated Sliding and Folding Doors” and Attachment 4 (Page 3 of 3)
and determine ANSI and IBC-2018 door operating requirements.