iQ Control Box

14      Document # 204144  REV B  •  www.stanleyaccess.com • 1.800.7.ACCESS 

Cop

yr

ight 2019, S

tanley Ac

cess T

echnologies, LL

C.

 

All rights r

es

er

ved. R

epr

oduction 

 

in whole or in p

ar

t without the expr

ess wr

itt

en permission o

f S

tanley is pr

ohibit

ed.

01.25.2019

Index

Min 

Value

Max 

Value

Description

Defaults

Single

Dual

36

1

60

Open Check 

 

Obstruction 

Time

Open Check Obstruction Time is the amount of time 

in increments of 0.025s the door applies force when 

almost stopped or stopped when the controller 

indicates a state of “04”.
Before increasing this parameter, check mechanical 

issues, and speed and torque parameter settings.

50

50

37

1

99

Open Check 

Torque

Open Check Torque is the torque used during 

 

normal operation in open check state.
This torque must be set to comply with ANSI/BHMA 

door force requirements.
This parameter sets the maximum current available 

to the motor which is directly proportional to the 

door force.  This torque setting is used in 

 

conjunction with open check speed.

40

40

39

1

99* Open Learn 

Speed

Open Learn Speed is the speed used on power up, 

during FIS, after an obstruction, and return from 

breakout. The controller display may indicate either 

02 or 04 as a door state and still use Open Learn 

Speed based on the conditions listed prior.
This speed is typically set higher then check speed, 

to allow faster door motion when not in the check 

zones, but still slower door motion than normal 

operation.
This parameter sets the target speed setting.  

 

Other parameters like open learn torque, and open 

 

acceleration as well as door properties like friction, 

door length, and door weight affect door speed.

25

25

40

1

99

Open Learn 

Torque

Open Learn Torque is the torque used on power up, 

during FIS, after an obstruction, and return from 

breakout.  
This torque must be set to comply with ANSI/BHMA 

door force requirements.
This parameter sets the maximum current available 

to the motor which is directly proportional to the 

door force.  This torque setting is used in 

 

conjunction with open learn speed.

48

25

41

1

60

Open 

 

Obstruction 

Time

Open Obstruction Time is the amount of time in 

increments of 0.025s the door applies force when 

almost stopped or stopped when the controller 

indicates a state of “02”.
Before increasing this parameter, check mechanical 

issues, and speed and torque parameter settings.

50

50

Table 3. Settings (continued)

Table 3 Settings continued next page.

Содержание Dura-Glide 2000

Страница 1: ...ing of statutory damages of up to 250 000 17 USC 504 for infringement and may result in further civil and criminal penalties All rights reserved All manuals can be found at www stanleymobileapps com i...

Страница 2: ...Glide 2000 3000 5200 5300 Dura Guard Dura Storm Dura Max 5400 Series ProCare 8300A and DuraCare 7500A TL FBO Automatic Slide door systems Instructions for connecting optional accessories are not prov...

Страница 3: ...anufacturer s installation and tune in instructions if installed Bluetooth adapter or cable to connect compatible handheld device to iQ Controller Degreaser Instructions for any other device to be wir...

Страница 4: ...erference Connecting Accessories As Applicable Refer to Attachments 2 and 3 and CONNECT any of the following subsystems to the iQ Controller Function switch rotary rocker and POWER switch wiring Stang...

Страница 5: ...n door noting rotation of belt pulleys If counter clockwise CCW use right hand during FIS If clockwise CW use left hand during FIS See figure below 5 FIS The first installation sequence FIS is used to...

Страница 6: ...e desired VALUE If the UP or DOWN buttons are not pressed within 2 5 seconds of releasing the ENTER button the display will change from the VALUE back to the STATUS 4 To display STATUS CODE A few seco...

Страница 7: ...otary The INDEX will start at 00 11 01 Rocker 00 Rotary A1 9 Select Lock Logic Lock Logic 00 Fail Safe 01 Fail Secure 02 Fail Safe Dura Max 03 Fail Secure Dura Max NOTE For locks with circuit board se...

Страница 8: ...tate 02 This speed is set to change how long it takes the door to open This parameter sets the target speed setting Other parameters like open torque open startup torque open startup length and open a...

Страница 9: ...on door weight and Close Speed setting 15 15 5 1 99 ReducedOpen Length ReducedOpenLengthisthepercentofdoorlength fromthefullopenpositionthedoorwillstopatifin reducedopenmode 1 1 6 1 99 Hold Open Dela...

Страница 10: ...e requirements This parameter sets the maximum current available to the motor which is directly proportional to the door force This torque setting is used in conjunc tion with close check speed 35 25...

Страница 11: ...eds close speed close check speed close learn speed as well as close braking 20 20 17 1 10 Close Braking The Close Braking parameter adjusts how quickly the door slows down prior to check speed Increa...

Страница 12: ...ther parameters like close check torque close acceleration and close braking as well as door properties like friction door length and door weight affect door speed 8 8 24 0 1 Access Control Pro Enable...

Страница 13: ...torque must be set to comply with ANSI BHMA door force requirements This parameter sets the maximum current available to the motor which is directly proportional to the door force This torque setting...

Страница 14: ...truction and return from breakout The controller display may indicate either 02 or 04 as a door state and still use Open Learn Speed based on the conditions listed prior This speed is typically set hi...

Страница 15: ...than Open Torque to ensure that the controller can start door motion overcome static friction and avoid obstructions This torque must be set to comply with ANSI BHMA door force requirements This param...

Страница 16: ...normally used with the selected input 0 Standard Functions NO Fire Alarm Input 1 Fire Alarm Input is TB2 9 Removes Functions Access Control Pro activation override Delayed Egress Reset and 4 Monitored...

Страница 17: ...pair bE Blocked egress c1 Position learn error Ld Lock down shear lock energized db Output control See Attachment 6 Sheet 2 of 2 dc Display door cycle counter dE Delayed egress d0 Free egress E2 Door...

Страница 18: ...d refer to Stanley Access Technologies document No 203768 StanguardTM Threshold Sensor Installation and Operation and TUNE IN StanguardTM threshold sensor Ensure that the JP301 Jumper is properly inst...

Страница 19: ...hnologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited Attachment 1 iQ Controls and Indicators Sheet 1 of 2 NOTE See next pa...

Страница 20: ...the display for tune in by pushbutton switches and indicates encoder movement High resolution encoder may be dim 10 Encoder 1 Connector Connection point for motor encoder No 1 11 Up Pushbutton Switch...

Страница 21: ...ment 204144 REV B 21 Copyright 2019 Stanley Access Technologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited Attachment 2 iQ...

Страница 22: ...ccess com 1 800 7 ACCESS Copyright 2019 Stanley Access Technologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited 01 25 2019...

Страница 23: ...om Document 204144 REV B 23 Copyright 2019 Stanley Access Technologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited Attachme...

Страница 24: ...1 800 7 ACCESS Copyright 2019 Stanley Access Technologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited 01 25 2019 Attachment...

Страница 25: ...ohibited Attachment 2 iQ System Wiring Diagram Sheet 5 of 10 TB6 COLOR DUAL HOLDING BEAM WIRING 1 YL OUTPUT UPPER RECEIVER 2 BK UPPER RECEIVER 3 YL OUTPUT LOWER RECEIVER 4 BK LOWER RECEIVER 5 OR TRANS...

Страница 26: ...Access Technologies LLC All rights reserved Reproduction in whole or in part without the express written permission of Stanley is prohibited 01 25 2019 Attachment 2 iQ System Wiring Diagram Sheet 6 of...

Страница 27: ...ut the express written permission of Stanley is prohibited Attachment 2 iQ System Wiring Diagram Sheet 7 of 10 TB3 COLOR PHOTO BEAM PRO BREAKOUT BEAM 1 RD JUMPER FROM TB3 5 2 BK JUMPER FROM TB3 6 3 NO...

Страница 28: ...em Wiring Diagram Sheet 8 of 10 X Zone ST For Security Applications 1 WAY Key DIP Switch settings 10 and 11 DOWN 12 13 14 15 and 16 UP X Zone ST and X Zone ST Key DIP Switch settings 10 and 11 DOWN 12...

Страница 29: ...Wiring Diagram Sheet 9 of 10 X Zone ST For Security Applications 1 WAY Key DIP Switch settings 10 and 11 DOWN 12 13 14 15 and 16 UP X Zone ST and X Zone ST Key DIP Switch settings 10 and 11 DOWN 12 1...

Страница 30: ...tanley is prohibited 01 25 2019 Attachment 2 iQ System Wiring Diagram Sheet 10 of 10 HR100 ST Recommended DIP Switch settings DIP Switch X 2 3 and 4 UP 1 DOWN DIP Switch Y 1 2 3 and 4 UP DIP Switch Z...

Страница 31: ...ON BL REDUCED OPEN VI COMMON VI HOLD OPEN BK COMMON YL AUTOMATIC RD COMMON OR ENTER ONE WAY BN REDUCED OPEN GN COMMON WH STANGUARD GN 24 VDC VDC COMMON WH OPTEXHOLDING BEAM GN BREAKOUT GN COMMON WH CO...

Страница 32: ...itivity Sensor pattern size sensitivity and function Knowing Act guidelines and secondary activating zone Entrapment protection rules including door speeds forces and time delays Signage Decals and ap...

Страница 33: ...nd similar Industrial Series 300 lbs 90 kg per panel Closing Speed Closing speed is measured over a travel distance of 2 or 3 feet On smaller bi part doors there may only be 2 feet of movement before...

Страница 34: ...justed so that the door s open at a speed of 12 inches per second maximum from fully closed to fully open When powered open the door shall remain at the fully open position for not less than 5 seconds...

Страница 35: ...n t Care Don t Care Terminal and Pin Description State TB3 4 StanguardTM Input Output Dark triggered or detecting TB3 8 TB4 8 Non Monitored Holding Beam Input Input and Outside Sensor connected intern...

Страница 36: ...oor hits Open Stop full open bumper Increase the Open Check Length Index 3 Door motion is not the same as the MC521 MC521PRO for the same settings Parameters value for the iQ are not the same as MC521...

Страница 37: ...Increase Open Speed Maximum setting is 99 with keypad or 125 with handheld Increase Open Torque Increase Open Acceleration NOTES Max Values go to 125 via handheld Open Torque is also used to set the...

Страница 38: ...Brake to Open Check Increase Obstruction Time from 5 seconds to 1 0 seconds Make small increases to Open Brake STALLS during closing without any obvious reason Continues to stall and it seems to happe...