Table 3. Settings (continued)
Index
Min
Value
Max
Value
Description
Defaults
Single
Dual
9
1
99
Close Torque
Close Torque is the torque used during normal
operation following the end of Close Startup Length.
This torque must be set to comply with BHMA/ANSI
door force equirements.
This parameter sets the maximum current available
to the motor which is directly proportional to the
door force. This torque setting is used in
conjunction with Close Speed.
30
25
10
1
99
Close Check
Torque
Close Check Torque is the torque used during normal
operation in close check state.
This torque must be set to comply with BHMA/ANSI
door force requirements.
This parameter sets the maximum current available
to the motor which is directly proportional to the
door force. This torque setting is used in conjunc-
tion with close check speed.
35
25
11
0
2
Function
Switch Type
00 = Double pole rotary
01 = Rocker
02 = ICU
1
1
12
0
1
2S Operation; 00 = 2S mode disabled / normal
01 = Push switch to open, push switch to close;
0
0
13
1
60
Close
Obstruction
Time
Close Obstruction Time is the amount of time in
increments of 0.025s the door applies force when
almost stopped or stopped when the controller
indicates a state of “07”.
Before increasing this parameter, check mechanical
issues, and speed and torque parameter settings.
50
50
14
0
40
Open
Acceleration
Open Acceleration affects the rate at which the door
gets to its target speed.
This parameter is used when the door is lagging
open speed; open startup torque and open startup
length should be investigated prior to increasing.
This parameter affects all open motion speeds: open
speed, open check speed, open learn speed, as well
as open braking.
30
30
Table 3 Settings continued next page.