204038
Rev. B, 4/12/08
Page 13 of 17
© 2008, THE STANLEY WORKS. ALL RIGHTS RESERVED.
Attachment 2
Delayed Egress Schematic Diagram (P/N 185063)
(Sheet 1 of 1)
-
RELAY K1
SOL. LOCK CONTROL
DUAL TRANSFER
CONTACT
SHEAR LOCK
DUMMY PUSH BAR
WITH SWITCH
24 VDC
POWER SUPPLY
RELAY
K2
SHEAR LOCK CONTROL
SW1
SW2
+
EGRESS ENABLE CONTACT
DUMMY PUSH BAR
WITH SWITCH
24 VDC OUTPUT
24 VDC INPUT
BUZZER
TB5-3 (EGRESS ENABLE)
DUAL TRANSFER
CONTACT
SHEAR LOCK
TB1-10 (0 VDC)
TB1-9
TB1-5 (BUZZER CONTROL)
SHEAR LOCK CONTROL
DUMMY PUSH BAR RELAY
FIRE ALARM INPUT
OR JUMPER
TERMINAL BLOCK
TB5-4 (COMMON)
TB5-10 (SHEAR LOCK
CONTROL)
DE- MC521
CONTROL BOX
P/N: 516928
TB1-1 (+15 VDC)
QUAD TRANSFER CONTACTS
BRIDGE
TB2-10
TB2-9
OPTIONAL
RESET SWITCH
BRIDGE
1
2
3
4
5
6
7
8
9
10
11
A1
A2
22
21
14
11
A1
A2
NC
C
NO
C
TB1-8 (SOLENOID LOCK CONTROL)
OR
RD
RD
RD
RD
BK
BK
BK
BL
GN
GN
GN
WH
WH
WH
WH
WH
WH
0
BRIDGE
TB1-2 (+24 VDC)
RD
BK
RD
12
GN
GN
GN
GN
WH
WH
WH
WH
GN
CHASIS
GROUND
WH
WH
WH
WH
GN
GN
GN
GN
INTERNALLY
CONNECTED
DE004
BL
GN
WH
RD
BK
RD
RD
BK