204038
Rev. B, 4/12/08
Page 16 of 17
© 2008, THE STANLEY WORKS. ALL RIGHTS RESERVED.
Attachment 3
Delayed Egress Wiring Diagram (P/N 185071)
(Sheet 3 of 4)
DE001_3A
FIELD DE-MC521 CONTROLLER WIRING
TO TB
516913
TO BUZZER AND BRACKET
ASSEMBLY P/N 415109
TB1 TB2
TB3 TB4 TB5
TB2
1
2
3
4
5
6
7
8
9
10
24-VDC
POWER SUPPLY
TB5
1
2
3
4
5
6
7
8
9
10
RD
WH
GN
BL
TB1
1
2
3
4
5
6
7
8
9
10
RD
BK
+
-
BK
OR
GROUND SHIELD
RESET SWITCH
(OPTIONAL)
SHIELDED GROUND