204038
Rev. B, 4/12/08
© 2008, THE STANLEY WORKS. ALL RIGHTS RESERVED.
4 of 17
3.
INSTALLATION INSTRUCTIONS
3.1
Installing the Door Panel Components
NOTE
For new or retrofit installations, the door panel components shown in Table 3-1 are pre-assembled and
wired in the factory.
Table 3-1. Door Panel Components
Part Name
Manufacturer
Part Number
2-Contact Block Assembly
Stanley Access Technologies
516909
2-Contact Plate Assembly
Stanley Access Technologies
516910
4-Contact Block Assembly
Stanley Access Technologies
516907
Recessed Panic Pushbar with Switch Adams Rite
185060
Detent Block for Delayed Egress
Stanley Access Technologies
516906
Shear Magnet Locks
GEM
714082
3.1.1
Refer to Figure 1, and, with the red wire at the top of the assembly, POSITION the 4-
contact block assembly at the lead edge of the hanger.
3.1.2
Using two #8-32 ½
″
pan-head screws and #8 external tooth washers, INSTALL the 4-
contact block assembly at the lead edge of the hanger.
3.1.3
Using a cable tie, SECURE the connector (and not the wires) to the tab.
Figure 1. Installing the 4-Contact Block Assembly
DE005
BOTTOM VIEW
CABLE TIE
GREEN WIRE
CONTACT
RED WIRE
CONTACT