204038
Rev. B, 4/12/08
Page 17 of 17
© 2008, THE STANLEY WORKS. ALL RIGHTS RESERVED.
Attachment 3
Delayed Egress Wiring Diagram (P/N 185071)
(Sheet 4 of 4)
DE001_4
FIELD POWER SWITCH WIRING
DE-MC521 CONTROLLER
P/N 516928
TB1 TB2
TB3 TB4 TB5
WH
WH
GN
RD
BK
RD
WH
8
7
2
ON
OFF
SCHEMATIC FOR THE
SWITCH REAR VIEW
COM
PIN 2
PIN 8
BK
WH
GN
HARNESS 412544 OR 412545
BK
GN
WH
3
2
1
3
2
1
LINE
NEUTRAL
EARTH GROUND
GROUND SCREW IN HEADER
120 VAC LINE
HARNESS 415117
POWER OFF
POWER ON
POWER SWITCH
P/N 415119
BK
RD