204038
Rev. B, 4/12/08
Page 15 of 17
© 2008, THE STANLEY WORKS. ALL RIGHTS RESERVED.
Attachment 3
Delayed Egress Wiring Diagram (P/N 185071)
(Sheet 2 of 4)
FIELD TERMINAL BLOCK WIRING
DE001_2
TO DE-MC521
TO 4-CONTACT PLATE
ASSEMBLY P/N 516908
EXISTING WIRING
(PART OF TB ASSY.)
21
11
24
14
A2
A1
RELAY
K1
22
12
NO
COM
NC
COIL
21
11
24
14
A2
A1
RELAY
K2
22
12
NO
COM
NC
COIL
10
9
8
7
6
5
4
3
2
1
LED
LED
RD
WH
GN
BK
GROUND SHIELD
RD
OR BK
GN BL WH