Page 67
HX851E
9 DSC SETUP MENU
The
HX851E
’s DSC Setup mode allows a number of the
HX851E
DSC param-
eters to be custom-configured for your operating requirement.
INDIVIDUAL DIRECTORY
- Refer to section 7.5.1
INDIVIDUAL REPLY
- Refer to section 7.5.2
INDIVIDUAL ACK
- Refer to section 7.6.1
INDIVIDUAL RINGER
- Refer to section 7.5.3
GROUP DIRECTORY
- Refer to section 7.7
POSITION REPLY
- Refer to section 7.8.1
DSC BEEP
- Individual - Refer to section 7.5.3
- Group - Refer to section 7.7.2
- All Ships - Refer to section 7.4.
- Position Request - Refer to section 7.8.2
- Position Report - Refer to section 7.9.1
- Geographic - Refer to section 7.10.1
DSC Scan
When the radio is shipped from the factory it is programmed so CH70 (the
DSC channel) is scanned at all times. This menu selection allows you to
disable the DSC SCAN. However, turning off DSC SCAN will disable the
radio from receiving DSC calls, (Individual Call, All Ships Call, Distress
Call and Position Requests. If you want to use any of the functions the
selection should be left ON.
1. Press and hold the [
CALL
(
ENT
)
MENU
] key
until “
Setup Menu
” appears.
2. Press the [
] key to select “
DSC Setup
” and
press the [
CALL
(
ENT
)
MENU
] key.
3. Press the [
] key to select “
DSC Scan
” and
press the [
CALL
(
ENT
)
MENU
] key.
4. Press the [
] or [
] key to select “
Off
” and
press the [
CALL
(
ENT
)
MENU
] key.
5. Press the [
16/9
] key to exit.
USER MMSI
- Refer to section 7.2.2