OTE:
N
The bottom line of a numeric-value display provides prompts regarding the function of each button. The [+] or [–]
button will change the value of the numeral. The [E] button will move the cursor one digit to the right. When the
cursor is at the final, right-most digit, pressing [E] will reposition the cursor at the left-most digit. The bottom line
display will change to reflect the new function of the [E] button. Press [E] to save the current entry. Press [+] to edit
the current entry.
LOW FLOW CUTOFF
% of 300.000 GPM
3.00%
EDIT:+ SAVE:E
Details on how to change and set numeric values are described in the following section.
Function Buttons
All SSK
513
programming is accomplished using the three function buttons located on the front of the amplifier:
OTE:
N
Throughout this manual, the buttons will be referred to as: [
] or [+] and [
] or [–], depending on the context. The
"Enter" button will be referred to as [E].
Consider the
[+ |
]
button as the "next step" or "scroll text up" button. During programming, pressing this button will
go to the next menu selection, or increment a numeral.
Example 1:
The illustration below shows the SSK
513
Main Menu.
The selection arrow is pointing to the Exit this Menu
selection.
To scroll up to the menu's next selection, press
[
]
once. The menu text scrolls up to the next menu selection,
Main Menu
.
START MENU
>Exit this Menu
Main Menu
MORE:
,
ENTER:>
Press [
]
START MENU
> Main Menu
Quick Setup
MORE:
,
ENTER:>
Example 2:
Some procedures require you to enter a numeric value. The [+] button is used to increment the selected numeral.
The illustration below shows the
Low Flow Cutoff
parameter display. Notice the cursor under the 2 in the ones' place. In this
case, press
[+]
once to increment the numeral to the value of 3.00%.
LOW FLOW CUTOFF
% of 300.000 GPM
2.00%
CHG: +,- NEXT:E
Press [+]
LOW FLOW CUTOFF
% of 300.000 GPM
3.00%
CHG: +,- NEXT:E
SSK
513
Electromagnetic Flow Meter
Page 22