11-2
Technical Specifications
07-01-08-02-E-V0500 631 Digital Servo Drive
Cabling Requirements for EMC Compliance
* For cable lengths longer than 15 and up to 50 metres contact Eurotherm Drives.
Resolver
Resolver
Resolver
Resolver
Power Supply
Power Supply
Power Supply
Power Supply
Cable
Cable
Cable
Cable
Motor Cable
Motor Cable
Motor Cable
Motor Cable
Brake Resistor
Brake Resistor
Brake Resistor
Brake Resistor
Cable
Cable
Cable
Cable
Signal/Control Cable
Signal/Control Cable
Signal/Control Cable
Signal/Control Cable
Cable Type
Cable Type
Cable Type
Cable Type
(for EMC
(for EMC
(for EMC
(for EMC
Compliance)
Compliance)
Compliance)
Compliance)
Screened
Unscreened
Screened/
armoured
Screened
Screened
Segregation
Segregation
Segregation
Segregation
From all
other
wiring
(sensitive)
From all other
wiring (clean)
From all other wiring (noisy)
From all other wiring
(sensitive)
Length Limitations
Length Limitations
Length Limitations
Length Limitations
With Internal AC
With Internal AC
With Internal AC
With Internal AC
Supply EMC Filter
Supply EMC Filter
Supply EMC Filter
Supply EMC Filter
50 metres
Unlimited
15 metres
domestic,
50 metres
****
industrial
2metres
25 metres
Screen to Earth
Screen to Earth
Screen to Earth
Screen to Earth
Connection
Connection
Connection
Connection
Both ends
Both ends
Both ends
Both ends
Fuse Rating and Recommended Wire Sizes
Refer to Chapter 9: “Accessories”
Local wiring regulations always take precedence.
* European wire sizes are based on EN60204-1 (1993) for PVC single-core cable bunched or
in trunking given a 70
ºC maximum conductor temperature under normal conditions in a 45ºC
ambient.
ª
ª
ª
ª
North American wire sizes are based on NEC/NFPA-70 for ampacities of thermoplastic-
insulated (60ºC) copper conductors assuming not more than three current-carrying conductors in
raceway or cable, based on ambient temperature of 30ºC. The wire sizes allow for an ampacity
of 125% of the rated input and output amperes for motor branch-circuit conductors as specified
in NEC/NFPA-70.
Input
Input
Input
Input
Output
Output
Output
Output
631
631
631
631
Product
Product
Product
Product
Code
Code
Code
Code
Input Fuse Rating
Input Fuse Rating
Input Fuse Rating
Input Fuse Rating
(A)
(A)
(A)
(A)
* European
* European
* European
* European
Wire Size (45ºC)
Wire Size (45ºC)
Wire Size (45ºC)
Wire Size (45ºC)
(mm²)
(mm²)
(mm²)
(mm²)
ª
ª
ª
ª
North American
North American
North American
North American
Wire Size
Wire Size
Wire Size
Wire Size
(AWG)
(AWG)
(AWG)
(AWG)
* European Wire
* European Wire
* European Wire
* European Wire
Size (45ºC)
Size (45ºC)
Size (45ºC)
Size (45ºC)
[for reduced cable
[for reduced cable
[for reduced cable
[for reduced cable
power losses]
power losses]
power losses]
power losses]
(mm²)
(mm²)
(mm²)
(mm²)
ª
ª
ª
ª
North American
North American
North American
North American
Wire Size
Wire Size
Wire Size
Wire Size
(AWG)
(AWG)
(AWG)
(AWG)
631/001
10.0
1.0
16
1.5
16
631/002
10.0
1.0
16
1.5
16
631/004
10.0
1.5
12
1.5 [2.5]
16 [14]
631/006
20.0
2.5
12
1.5 [2.5]
16 [14]
Terminal Block Wire Sizes
Wire sizes should be chosen with respect to the operating conditions and your local National
Electrical Safety Installation Requirements.
Power Terminals (X1)
Power Terminals (X1)
Power Terminals (X1)
Power Terminals (X1)
Maximum acceptance for aperture: 12 AWG (3.3mm²)
Control Terminals
Control Terminals
Control Terminals
Control Terminals
(X10)
(X10)
(X10)
(X10)
0.08mm² - 2.1mm² (28 AWG - 14 AWG)
Communication Terminals
Communication Terminals
Communication Terminals
Communication Terminals
(X20 / X21, X40 / X41)
(X20 / X21, X40 / X41)
(X20 / X21, X40 / X41)
(X20 / X21, X40 / X41)
26 AWG
For information:
12 AWG (3.3mm²), 14 AWG (2.5mm²), 18 AWG (0.8mm²), 20 AWG (0.5mm²) 22 AWG (0.3mm²)