SS-16 VoIP-2-GSM USER MANUAL
DOC. NO: SS-16-14 (REV. 02)
Page 76 of 84
TITLE
DESCRIPTION
Concurrent
service (Based on
UMTS)
1 UMTS CS voice + 1 UMTS PS data only for devices fitted with 3G
modules
SMS
Supporting SMS based on CS domain of GSM or UMTS Supporting SMS
based on PS domain of UMTS
Mobile antennas
External quad-band antennas with magnetic base and cable
Supply voltage
12 V
D.C
. (+ centre wire, - external conductor)
Supply adapter
Special adapter, Dee Van Enterprises Ltd. Type: DVE DSA-30PF-12
output : 12 V
D.C
. / 2 A
Input: from 100 to 240 V
A.C
. / 0,3 A / 50 Hz
Status indicators
Three bicolor LEDs, for Status, Mobile 1, Mobile 2
Temp. range
Operating: 5
0
.... 50
0
C
Storage: 0
0
.... 60
0
C
Dimensions
(L x W x H)
222 x 115 x 32 (mm) except protrusions
Weight
500 g – SS-16 VOIP-2-GSM unit
1 kg – the whole package
7.5
OPERATING ENVIRONMENT
SS-16 VOIP-2-GSM was designed for indoor use only, so you should NOT operate it
outdoors.
Install the SS-16 VOIP-2-GSM in closed rooms or enclosures, where the
environmental conditions should be:
operating temperature range: from 5 to 50 degrees C
relative humidity: from 10 to 85 %, non-condensing
Avoid dust and prolonged exposure to sun. In addition, The SS-16 VOIP-2-GSM must
NOT be used in a flammable or explosive environment, or in locations where toxic or
flammable gases may accumulate.
The equipment must be handled with care, to avoid mechanical shocks and blows.
The SS-16 VOIP-2-GSM should not be used in an environment with high level of EMI
(electromagnetic interferences) that is in close proximity to high power equipment
such as electric motors or heaters. In addition, it should not be placed near copiers,
PC monitors, TV sets or other audio-video appliances.
In order to ensure adequate working temperature, the SS-16 VOIP-2-GSM interface must not be
used too close to heat sources or in direct sunlight.
Also, it must not be overcrowded: leave free space around, below and above the SS-16 VOIP-2-
GSM router. This is needed both for connecting Ethernet and antennas cables, and also for
ventilation (natural air cooling to dissipate the heat generated during operation).
When allowed operating temperature is exceeded this may not have an immediate, visible effect on
the SS-16 VOIP-2-GSM unit, but it can result in unreliable operation, accelerated ageing and hence
diminishing of lifetime.
When selecting the location for installing the external antennas of the SS-16 VOIP-2-GSM, refer to
the recommendations described in the chapter about mounting the equipment.
The SS TELECOMS SS-16 VOIP-2-GSM does not include materials or components that are
harmful to the environment.