Inspection and Measurement
Inspection point: T611 motor voltage test at the drive board
Inspection method: 1. Select the VDC setting on the multi-meter. Place probes on M+M- connectors on the drive board.
2. Press the SPEED<
▲
> key. The motor should operate, allowing you to measure motor voltage.
Speed
Drive board voltage
Motor specifications
Highest speed
100-120 VDC
110V
Lowest speed
210-230 VDC
220V