Inspection and Measurement
Inspection point: T611 optic wheel, optic sensor
Inspection method: 1. Inspect the optic wheel placement. The optic wheel should rotate in the center of the optic sensor.
It should not touch the optic sensor.
2. Inspect whether optic wheel teeth have broken.
3. Pull the walk belt to allow the optic wheel to move. Inspect whether LED7 on the drive board flashes.
When a tooth of the optic wheel is in the center of the optic sensor, LED7 on the drive board does not light.
When a tooth of the optic wheel is not in the center of the optic sensor, LED7 on the drive board lights.
4. The optic sensor includes an infrared transmitter and a receiver. Inspect whether the optic sensor is dirty.
If so, wipe it clean.
4-1-1
LED7 optic sensor signal indicator
Optic sensor
Optic wheel