Troubleshooting
Model: T611
Malfunction: Telemetry heart rate malfunction
Circumstance: Telemetry heart rate malfunction
Possible cause:
1. Transmitter battery voltage is too low.
2. Telemetry receiver board malfunction
3. Environmental interference, possibly from lights
or speakers
Troubleshooting:
1. Replace the transmitter strap or its batteries.
2. Inspect the receiver board wire connection.
3. Replace the receiver board.
3-3-1
Heart rate
receiver
Display
board
Transmitter
Telemetry transmitter
(battery location)
Telemetry heart rate
receiver board
HR LED