Troubleshooting
Model: T611
Malfunction: The fuse has broken.
Circumstance: Press the speed key. Motor rotates. Fuse blows.
Possible cause: 1. Motor has an abnormal, internal electrical short.
2. Drive board malfunction
Troubleshooting: 1. Replace the drive board as a test.
2. Replace the motor as a test.
3. Replace the optic sensor as a test.
3-8-2
Drive board
Display board
Sensor
Motor
Drive board
Motor
Sensor