Troubleshooting
Model: T611
Malfunction: Err 1
Circumstance: Press Speed key. Motor rotates. Err1 appears.
Possible cause: 1. Motor rotates
optic sensor malfunctions
Troubleshooting: 1. Inspect all cable connections.
2. Inspect whether CLK indicator on drive board flashes.
If not, optic sensor is malfunctioning. Suggestion:
A. clean the optic sensor sensor head.
B. replace the optic sensor.
3. If the CLK indicator lights, inspect:
A. cable connections
B. main IC connections.
3-9-2
Drive board
Display board
Sensor
Motor
Inspect the display cable connections and the IC
connection.
Motor
Inspect motor brushes
CLK indicator
Inspect the optic sensor