Troubleshooting
Model: T611
Malfunction: Safety key malfunction
Circumstance: Put the safety key in place. The display shows no reaction.
“Safety key” appears.
Possible cause: Safety key board malfunction
Troubleshooting: 1. Inspect the safety key magnet.
2. Inspect bridge board connections.
3. Test or replace the safety key board.
3-1-1
Display
Board
Bridge
board
Safety key
board
Safety key board
Safety key cable
Safety key reed switch test
Put safety key
magnet in place
Reed switch: electrical
continuity
ON
Do not put the
safety key magnet
in place
Reed switch: electrical
open
OFF