These Installation and Maintenance Instructions explain how to correctly install,
commission and maintain the RIM10 Series of rotor insertion flowmeters.
2.1 Product description
The RIM10 Series of rotor insertion flowmeters are designed to reduce the cost of
flowmetering and record total flow by accurately measuring steam, liquid or gas flowrates.
2.2 Copyright notice
Copyright © Spirax Sarco, Inc.(2010)
All rights reserved.
Spirax Sarco, Inc. grants the legal user of this product (or device) the right to use the
Work(s) solely within the scope of the legitimate operation of the product (or device).
No other right is granted under this license. In particular and without prejudice to the
generality of the foregoing, the Work(s) may not be used, sold, licensed, transferred,
copied or reproduced in whole or in part or in any manner or form other than as expressly
granted here without the prior written consent of Spirax Sarco, Inc.
2.3 Equipment delivery and handling
Factory shipment
Prior to shipment, the Spirax Sarco RIM10 is tested, calibrated and inspected to ensure
proper operation.
Receipt of shipment
Each carton should be inspected at the time of delivery for possible external damage. Any
visible damage should be recorded immediately on the carrier's copy of the delivery slip.
Each carton should be unpacked carefully and its contents checked for damage. If it is
found that some items have been damaged or are missing, notify Spirax Sarco immediately
and provide full details. In addition, damage must be reported to the carrier with a request
for their on-site inspection of the damaged item and its shipping carton.
Contact details for the RIM10 range of products:
Spirax Sarco, Inc.
2150 Miller Drive, Longmont, CO 80501
T: 800.356.9362 or 303.682.7060
F: 303.682.7069
www.spiraxsarco.com/us
Storage
If a flowmeter is to be stored prior to installation, the environmental storage conditions
should be at a temperature between 0°C and 70°C (32°F and 158°F), and between 10%
and 90% relative humidity (non-condensing).
Calibration data - Important
Save the RIM10 calibration and application information data sheets when unpacking
your new flowmeter. These data sheets are important in setting up and monitoring the
performance of your new flowmeter.
2. General product information
and Guide to installation