IM-P198-02
MI Issue 5
17
3.2.5 Rotor orientation and final positioning
Use the retractor handle to carefully insert the rotor down into the pipe until the calculated
insertion depth figure on the depth scale lines up with the top of the cursor. Use a pipe
wrench to align the retractor bar assembly so the flow direction arrow on the cursor is in
line with the pipe and pointed downstream. Lock the stem in position by tightening the
orientation set screw - See Figures 11 and 12.
Caution:
Do not allow the orientation of the flowmeter or the insertion depth to change
after insertion is complete. A change in insertion depth or alignment will cause inaccurate
readings and shorten rotor life.
Fig. 11 RIM10-900
Orientation
set screw
Fig. 12 RIM10-600
Orientation
set screw