12
3.2 RIM10-600 and RIM10-900 hot tap and cold tap installation
3.2.1 Hot tap installation: M-TMP-600 and M-TMP-900
Caution - Risk of danger:
Hot tap installation must only be done by qualified personnel.
The RIM10-600 and RIM10-900 can be installed without process shutdown or line
depressurisation. The RIM10-600 is shipped with an isolation valve and a pipe nipple
attached to the flowmeter - See Figure 6. For a hot tap installation, the isolation valve and
pipe nipple need to be separated from the flowmeter. Use Steps 1 to 5 as a guide.
Fig. 6 RIM10-600
Fig. 7 RIM10-900
Bleed
valve
Bronze
isolation
valve
Pipe nipple
Thread-o-let
Weld-o-let
Ball
or
Gate valve
Bleed
valve
Scale
reading
Wheel
E
I
wt
wt
E
I
Both the Ball and Gate valve are
available from Spirax Sarco
*
*