Fault Finding Procedure: CSM-C Compact Clean Steam Generator
Fault Finding
The following table summarizes problems that may be encountered during the life of a
CSM-C Compact Steam Generator, and the procedures to remedy those problems.
Symptom
Cause
Remedy
Water Level in tank is
too low. Tank is in alarm
condition.
No feed water available.
Check that water supply
treatment plant is running
and that water is available.
Check that isolation valve is
open.
Water Feed PAV is not open. Check that air supply
pressure is correct.
Check that PAV solenoid
valve is energised.
Operate manual override on
solenoid valve to check
operation of valve.
Manually operate valve via
tank synoptic screen on
controller.
Water level transducer is
damaged and giving false
reading.
Replace level transducer.
Contact Spirax Sarco Service
Department.
Water Level in tank is too
high.
Tank is in alarm condition.
Water feed PAV has failed to
close.
Isolate feed water system
and inspect valve seat for
damage (see appropriate
instruction manual).
Water supply pressure
exceeds maximum
differential pressure of valve.
Check water supply
pressure.
Water level transducer is
damaged and giving a false
reading.
Replace level transducer.
Contact Spirax Sarco Service
Department.