HMP100 User Guide v2.1
25
Validate the new network configuration with the
Apply
button.
Troubleshooting
Once the device has rebooted, you can check the new configuration by accessing the
HTTP server. Note that you need to use the new IP address this time. If you are not able
to connect to your HMP100 unit after modifying the IP configuration, please read the
following suggestions before contacting the SpinetiX support team.
1) Check the LED on you HMP100 unit.
If the LED is blinking once per second in orange color and the red led is bright on then
you are in one of the following cases
The IP address of your HMP100 unit has already been assigned on the network.
Check your network configuration and make sure that the address <new IP> is
not taken by another device. If the unit is using a firmware 2.1 or above, it will
use an auto configured IP in the range 169.254.0.1-169.254.255.254.
Your HMP100 unit has been configured to activate DHCP but no DHCP server has
been detected on your network. Make sure you have selected the
Static
radio