hyphen. Using an empty device name will reset the name to its default value, which is the serial number
of the HMP device.
For instance, to reset the device name to the default value, use:
<device-name></device-name>
To setting the device name to a given value, use:
<device-name>office-screen</device-name>
Controls the network watchdog parameters. If set to a value other than 0, the network watchdog is
activated. When activated, the device will reboot if one of the condition is no longer valid. Link-local
(i.e. Zeroconf) addresses are not taken into account.
The watchdog may be used in case of 3G modem as it is sometimes necessary to reset the 3G dongle
by doing a reboot of the HMP to restore a lost connection.
This command is composed of the following parameters:
<max-time-no-addr>
Maximum time the device is allowed to stay without an assigned IP address.
<min-time-keep-addr>
Minimum amount of time an IP address should stay valid before a new one is assigned
to the player.
Both parameters can be configured using a time in second (10s), minute (10m) or hour (1h).
For instance, to disable the network watchdog, use:
<network-watchdog>
<max-time-no-addr>0s</max-time-no-addr>
<min-time-keep-addr>0s</min-time-keep-addr>
</network-watchdog>
To enable the network watchdog, use:
<network-watchdog>
<max-time-no-addr>2m</max-time-no-addr>
<min-time-keep-addr>90s</min-time-keep-addr>
</network-watchdog>
Configure proxy settings needed to access the internet.