© Titan Tool Inc. All rights reserved.
13
Airless Tip Selection
REMEDY
1. Inspect connections for
air leaks
2. Disassemble and clean
3. Inspect and adjust
4. Inspect and replace
1. Replace
2. Adjust
3. Clean
1. Check fluid supply
2. Clean
3. Replace
PROBABLE CAUSE
1. Air in system
2. Dirty gun
3. Needle assembly out of adjustment
4. Broken or chipped seat
1. Worn or broken needle & seat
2. Needle assembly out of adjustment
3. Dirty gun
1. No paint
2. Plugged filter or tip
3. Broken needle in gun
PROBLEM
Spitting gun
Gun will not shut off
Gun does not spray
Troubleshooting Airless Gun
Tips are selected by the orifice size and fan width. The proper selection is determined
by the fan width required for a specific job and by the orifice size that will supply the
desired amount of fluid and accomplish proper atomization.
For light viscosity fluids, smaller orifice tips generally are desired. For heavier
viscosity materials, larger orifice tips are preferred. Please refer to the chart below.
The following chart indicates the most common sizes and the appropriate materials to
be sprayed:
.011 - .013
Lacquers & Stains
100 Mesh Filter
.015 - .019
Oil & Latex
50 Mesh Filter
.021 - .026
Heavy Bodied Latex & Blockfillers
5 Mesh Filter
Fan widths measuring 8" to 12" (20 to 30 cm) are most preferred because they offer
more control while spraying and are less likely to plug.
NOTE: Do not exceed the pump's recommended tip size.
Содержание 449-500
Страница 30: ...30 Titan Tool Inc All rights reserved Notes...
Страница 31: ...Titan Tool Inc All rights reserved 31 Notes...