![Spectracom GSG-5 series Скачать руководство пользователя страница 243](http://html1.mh-extra.com/html/spectracom/gsg-5-series/gsg-5-series_user-manual-with-scpi-manual_1343630243.webp)
Example
SEND:
SOURce:POWer?
READ:
-121.3
6.3.3.3
SOURce:REFPOWer
Function
Changes the absolute power in dBm of the reference signal (GPS L1 C/A).
Command Syntax
SOURce:REFPOWer <decimal>
Notes
This command can only be used before starting a simulation. The setting is not stored during
scenario or 1-channel mode execution.
If power is inside allowed limits, but other RF parameters need to be modified, such parameters
are modified and an error about a settings conflict is set.
Parameter
decimal [-160,-65] dBm
Example
SEND:
SOURce:REFPOWer -123.2
You can use the keyword “default” instead of
<power>:
SOURce:REFPOWer default
Restores default relative power for GPS L1 C/A
6.3 Command Reference
CHAPTER
6
•
User Manual GSG-5/6 Series
Rev.
26