Trouble Shooting - continued
PROBLEM
POSSIBLE CAUSES
SOLUTION
7. Motor overload
protection “kicks out”.
a. Motor is not connected properly.
b. Low voltage due to under size
wire or low incoming voltage.
c. Wrong size heaters in protective
device.
d. Overload due to binding in pump
or wrong size impeller.
Check wiring diagram on motor.
Check with volt meter. Increase size of supply wire.
Report low supply voltage to power company. Voltage
at motor must be within 10% of motor nameplate
voltage.
Heaters should be one size larger than full load amps
shown on motor nameplate.
Indicated by high amperage readings on motor, binding
shaft. Disassemble unit and correct.
8. The LED light is not
working?
a. Moisture in air tubing or bad air
button.
b. Control Box.
Remove air tubing from air switch at control box. Con-
nect a short piece of air tubing to the L.E.D. air switch.
Blow into tube and check if L.E.D. turns on/off.
Contact certified electrician to diagnose control box
components.
9. The volume control
knob keeps spinning?
a. Broken Spindle.
Contact the factory 800-223-8538
10. My ON/OFF air
button is not working
properly?
a. Control Box.
b. Air tubing.
Check GFCI. If green LED does not stay ON, contact a
certified electrician to diagnose control box compo-
nents.
Check air tubing connection on the control box. Check
that the tubing is not bent or pinched. Tubing may
need to be replaced.
11. The system will not
turn OFF?
a. Control Box Components.
Press TEST button on the control box GFCI to turn off
system. Contact a certified electrician to diagnose con-
trol box components.
12. I have the volume
control knob turned com-
pletely up but the flow is
weak?
a. Debris in pump casing/impeller.
b. Improper swim jet assembly.
Check inside pump casing for any debris.
The internals may need to be removed for inspection
of the spindle.