WARNING: 

Before Installing this product, read and follow all warning notices and instructions which are included. 

Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 
1-800-223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.

 

Important Safety Instructions

Swim Jet Combination Fitting - Manufacturers Warnings

MUST BE INSTALLED by an experienced and qualified pool industry professional ONLY.

Attention Installer: This manual contains important information about installation, operation, and safe use of 
this product. This information should be given to the owner and/or operator of this equipment. Most Federal, State 
and Local codes regulate the construction, installation and operation of pools and spas. It is important to comply 
with these codes, many of which regulate the installation and use of this product.

1. 

DO NOT locate this fitting in seating areas or on the back rests for such seating areas.

2.

 This fitting should be mounted in the vertical pool wall only per manufacturer’s instructions.

3. 

All fittings and fasteners should be examined for damage or tampering before each use.

 
4. 

Any missing, broken, or cracked fittings must be replaced before using this product. Only genuine Speck 

replacement parts may be used.

5. 

Acceptable fittings/pipe sizes are listed on page 7 of this manual. No other sizes are permitted.

 
6. 

Never exceed the maximum flow rate stated on this product.

7. 

The anti-entrapment cover must be in place when using this product. DO NOT use this product if the cover is 

missing, broke or loose.

8. 

The stainless steel anti-entrapment cover (part# 93.1) should be replaced within 20 years from installation 

date. The suction housing (part # 93) should be replaced within 10 years from installation date.

9. 

Installation requires a Phillips screw driver. All screws should be hand tight only. DO NOT use electrical or air 

drills.

10. 

Consult your physician before exercising with the BaduJet Imperial or using the massage hose.

11. 

DO NOT permit children to use this product unless they are closely supervised at all times.

12. 

DO NOT remove any safety alert labels such as

 

DANGER, WARNING,

 

or CAUTION

Keep safety alert labels in 

good condition and replace missing or damaged labels.

13. 

Stay alert, watch what you are doing and use common sense. DO NOT use unit if you are tired and/or 

exhausted.

 

DO NOT use unit while under the influence of drugs, alcohol, or any medications

14. CAUTION: 

DO NOT increase pump size; this will increase the flow rate through the system and exceed the 

maximum flow rate stated on this product.

  

IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY PRESENT A RISK OF HAIR OR BODY ENTRAPMENT 

AND DROWNING.

 

Install this equipment in accordance with the instructions provided.

Содержание badu jet imperial

Страница 1: ...Installation Manual BADU JET IMPERIAL Counter Swimming Unit Rev 03 16...

Страница 2: ...pment 2999999303 Rev 0416 SW OO 0 OO Technical Support Address Speck Pumps 8125 Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739...

Страница 3: ...Plumbing Installation 7 New Concrete or Gunite Installation 9 Existing Concrete or Gunite Installation 13 Liner and or Fiberglass Pool Installation 14 Bonding Instructions 16 Final Assembly 17 Electr...

Страница 4: ...nt parts may be used 5 Acceptable fittings pipe sizes are listed on page 7 of this manual No other sizes are permitted 6 Never exceed the maximum flow rate stated on this product 7 The anti entrapment...

Страница 5: ...l or one each on two separate vertical walls WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increased potential fo...

Страница 6: ...6 2011 Suction Fittings for Use in Swimming Pools Wading Pools Spas and Hot Tubs and either A B A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release Syst...

Страница 7: ...N The discharge connection on the back of the jet housing must be located directly ABOVE the suction connection CAUTION The suction line should remain below water level from the suction connection at...

Страница 8: ...reduce the performance of the system The shortest length of pipe with the minimum number of fittings possible should be used to avoid any significant friction loss due to the pipe and fittings NOTE Re...

Страница 9: ...NOTE To avoid stress on the housing the jet housing and 2 to 3 inches of plumbing conduit stub out should be encased in gunite or concrete Figure 3 Sample BaduJet Imperial Installation Self Priming 1...

Страница 10: ...it to a point above the water line for example at the equipment pad Install the 1 2 check valve part 101 O ring part 113 and 1 2 conduit adapter part 116 at the end of the 1 2 conduit n n Glue the met...

Страница 11: ...steel handles part 70 based on your pool construction Mount the gunite cover to the front of the jet housing using the four 4 M8 x 80mm studs part 31 four 4 M8 washers part 32 and four 4 M8 nuts part...

Страница 12: ...re 5 to mark and drill the holes through the liner twelve 12 M8 clamping ring screw holes and 13 3 center hole Insert the gasket with knobs in the front of the jet housing part 26 Install the liner wi...

Страница 13: ...ide of pool wall 7 Mix compound that is compatible and has a good bonding characteristics to the pool wall compound Pour mixture into form Use a mallet and lightly tap the front of formed assembly to...

Страница 14: ...r not silicone is necessary Discharge connection Air Regulator Hose Connection Suction connection Protective Conduit Connection L E D Light Cable Air Hose Bonding Adaptor Figure 11 Jet Housing Rear Vi...

Страница 15: ...ng ring screws part 52 9 Follow steps 1 4 under Jet Housing Installation New Gunite or Concrete Construction on page 9 10 10 Continue to Final Assembly Section on page 17 NOTE The gunite cover part 30...

Страница 16: ...front of the jet housing See Figure 16 3 After installing the nozzle housing part 102 1 in Final Assembly Section on page 17 pull the bare end of the wire through the bonding lug on the stainless stee...

Страница 17: ...94 and four 4 M8 x 20 suction cover screws part 95 All screws should be HAND TIGHT DO NOT use drills or pneumatic tools DO NOT over tighten Make sure the UP label is in the correct position See Figur...

Страница 18: ...ween pump and pool Locate pump as close to the pool as practical CAUTION There is 30 ft of air tubing for the air buttons as well as 30 ft of cable for the LED light included with the BaduJet Imperial...

Страница 19: ...n GROUNDING Permanently ground the pump motor and control box using a conductor of appropriate size CAUTION DO NOT connect to electric power supply until the unit is permanently grounded Power from m...

Страница 20: ...ntrols C N O N C BLK 6 YEL 1 GROUND SERVICE Single Motor 7 YEL 3 BLU 1 YEL 3 BLU 1 To Control From Control N C N O C Remote Relay 07 03 2014 GFCI Module WHT 1 BLK 2 RED 2 ORG 0 YEL 0 ORG 0 BLK 6 Trans...

Страница 21: ...ssary High levels of chlorination can be minimized or eliminated through careful water management 6 When shocking the pool the pump should be maintained on its highest speed until chlorine levels retu...

Страница 22: ...one 1 winter plate one 1 gasket four 4 M8 washers and four 4 M8 x 30mm screws See Figure 27 Also you can protect your swimjet system as follows Drain pool until water level has dropped below the anti...

Страница 23: ...air from the top of the water level If installed too low a good swim lane cannot be developed Can the pump be placed below water level Yes However for best performance we recommend ordering a pump fo...

Страница 24: ...Bad bearings Check for noise when shaft is turned by hand Motor will be very hot in bearing area when running Replace bearing 5 Motor runs hot These motors will run hot to the touch however this is n...

Страница 25: ...a short piece of air tubing to the L E D air switch Blow into tube and check if L E D turns on off Contact certified electrician to diagnose control box components 9 The volume control knob keeps spin...

Страница 26: ...28 102 1 61 70 95 93 1 94 93 110 112 37 38 1 38 2 111 21 1 47 62 9 4 48 23 102 64 65 66 67 63 109 108 58 56 54 59 60 102 1 22 21 107 6 4 101 25 20 113 114 115 116 117 118 31 32 33 98 119 26 6 Product...

Страница 27: ...EALING CORD GASKET WITH KNOBS JET HOUSING GASKET CLAMPING RING RING CLAMPING GUNITE COVER STUD GUNITE COVER M8 x 80mm WASHER GUNITE COVER M8 NUT STUD GUNITE COVER M8 A2 O RING PNEUMATIC BUTTONS 24 x 3...

Страница 28: ...be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to Buyer or with respect to the Badu SwimJet System s in the event of the occ...

Страница 29: ...AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF SPECIAL INDIRECT INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES OR LOSS SO TH...

Страница 30: ......

Отзывы: