Electrical Installation - continued
Pump Motor: Connect to the No. 10 green headed ground screw provided inside the motor terminal box.
Control Box: Connect to the aluminum grounding terminal strip on the inside of the control box enclosure.
n
n
GROUNDING: Permanently ground the pump motor and control box using a conductor of appropriate size.
CAUTION: DO NOT connect to electric power supply until the unit is permanently grounded.
Power from main panel (230 VAC):
Neutral, Line 1, Line 2
Power to pump motor (230 VAC):
Load 1, Load 2
Connection to remote relay
(120 VAC)
Connection to LED Light
(12 VAC)
Ground connections from
main panel and pump motor
Figure 24
Control Box Wiring Connections