23
Frequently Asked Questions
What size pool do I need?
The BaduJet Imperial can be installed in any size pool. However, we recommend a minimum length of 14 ft and a minimum
width of a 7 ft. swimming lane.
What size plumbing is necessary? How far away from the BaduJet Imperial can the pump be installed?
Use 4” plumbing up to 30 ft. For runs longer that 30 ft use 6” plumbing. The pump should be placed as close to the BaduJet
Imperial as local codes will allow.
How many amps does the pump operate at?
4.0 HP: Maximum 21.0 - 19.4 Amps @ 208-230 V
What size breaker do I need?
You must use a 40 amp breaker for the 4 HP pump to avoid nuisance tripping.
Does the LED light come in different colors?
Yes. The LED light comes in blue or a multi-color option.
Does it matter if the housing is installed higher or lower than the manual states?
Yes, the center of the jet must be 12” BELOW estimated water level for proper performance of unit. If installed too high, the
pump will draw in air from the top of the water level. If installed too low, a good swim lane cannot be developed.
Can the pump be placed below water level?
Yes. However, for best performance we recommend ordering a pump for flooded suction (Model 21-80/33G) instead of self-
priming (Model 21-80/33GS). We recommend installing valves when installing below water level for ease of maintenance.
Do I need to install a motor starter?
In most cases, no. All single phase pumps have built-in thermal overloads. Also, the three phase Model 21-80/33 has built-in
thermal overload. Other three phase pumps require a motor starter.
Should the swimjet system be tied into the filter system?
No. The swim jet system and the filter system should not be plumbed together as they each provide very specific functions.
Can I use it with automated controls?
Yes. It comes with the ability to tie into automated control systems or other switching devices.
Is the BaduJet Imperial approved?
Yes. The BaduJet Imperial swim jet system is listed by UL and complies with ASME standard A
NSI/ASME A112.19.8 (ANSI/
APSP-16, 2011)
Standard for Swim Jet Combination Fittings, and is VGB 2008 compliant.