4”
Service
Disconnect
Control
Box
Pneumatic
Hose
Pump
Discharge Line
Valves (Optional)
4”
4”
4”
6” Riser
Maximum 4 Feet
Vertical
Discharge Connection
(Discharge Line)
Vertical Suction Line
Horizontal
Discharge Connection
(Discharge Line)
Horizontal Suction Line
max. 30 feet with 4” pipe
Check Valve (Optional)
(Below Water Level)
3/4” Conduit
(Pneumatic Hoses & Light Cables)
Water Level
4”
~12”
1/2” Conduit
(Air Regulator)
9
Plumbing - continued
NOTE: Valves are recommended when pump is installed
below water level (flooded suction applications).
NOTE: To avoid stress on the housing, the jet housing and
2 to 3 inches of plumbing/conduit stub out should
be encased in gunite or concrete.
Figure 3
Sample BaduJet Imperial Installation (Self-Priming)
11.5”
~12.0”
DISCHARGE
4” SLIP CONNECTION
SUCTION
4” SLIP CONNECTION
WATER LEVEL
WATER LEVEL
14.0”
13.5”
15.0”
3.8”
9.4”
5.2”
CENTER LINE
18.6”
~12.0”
6.7”
23.0”
Figure 4
BaduJet Dimensional Drawing
Jet Housing Installation - New Concrete or Gunite Construction
CAUTION: All necessary screws and bolts included with the BaduJet Imperial are stainless steel. ALL screw threads and
threaded inserts are METRIC! ONLY METRIC bolts and nuts may be used! All screws should be HAND TIGHT. DO NOT use
drills or pneumatic tools. DO NOT over tighten!