![Speck pumpen BADU BADUJET Turbo Pro Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/speck-pumpen/badu-badujet-turbo-pro/badu-badujet-turbo-pro_translation-of-original-operation-manual_1341777042.webp)
Commissioning/Decommissioning
42 EN
08|2020
6.2.2 Volume
regulation
WARNING
Risk of damage to health!
Keep a safe distance from the current nozzle (ball nozzle
(42)).
The volume can be regulated by pressing the upper and lower
piezo buttons (64) installed in the panel (55) or by the remote
control unit (66).
Panel
Arrow up
Increase volume flow
Arrow down
Reduce volume flow
Remote control
+
Increase volume flow
-
Reduce volume flow
The system can be controlled over a speed range from 750 rpm to
1650 rpm. The individual power stages are additionally indicated
visually by changing colours on the buttons.
yellow flashing
1650 rpm
yellow 1500
rpm
violet 1350
rpm
green 1200
rpm
blue System off
red System
on
green 1200
rpm
turquoise 1050
rpm
blue 900
rpm
blue flashing 750
rpm
In the boost position (max. volume flow; speed 1650 rpm) the
volume regulation automatically switches back one stage after
15 minutes operating time (safety setting, then off-time).
Содержание BADU BADUJET Turbo Pro
Страница 1: ...EN EN Translation of original operation manual Submerged counter swim unit ...
Страница 20: ...Installation 20 EN 08 2020 Pool cutout for concrete pools formwork Fig 4 ...
Страница 21: ...Installation 08 2020 EN 21 Installation of formwork for concrete pools Fig 5 ...
Страница 34: ...Installation 34 EN 08 2020 5 4 4 Control cable wiring diagram Fig 18 ...
Страница 38: ...Installation 38 EN 08 2020 5 4 7 On off board circuit diagram Fig 20 5 4 8 Terminal box connections Fig 21 ...
Страница 49: ...Technical Data 08 2020 EN 49 10 2 Exploded drawing Fig 26 ...