![Speck pumpen BADU BADUJET Turbo Pro Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/speck-pumpen/badu-badujet-turbo-pro/badu-badujet-turbo-pro_translation-of-original-operation-manual_1341777028.webp)
Installation
28 EN
08|2020
5.3.2 Installing the nozzle unit
1. Insert the nozzle unit (4) with its 3 fastening domes into the
cylindrical depression of the housing centring/flange centring.
2. Tighten the three tapping screws (6x40 (46)) with a torque of
6 Nm.
Fig. 13
NOTICE
Appropriate adapters (45) must be installed between the housing
and the nozzle unit (4) for a pool wall thickness from 3.5 mm up to
max. 27 mm.
The adapter height must be chosen so that the round panel (52)
has no gap bigger than 8 mm from the maximally swivelled ball
nozzle (42) in the installed state.
The following order kits must be used above a wall thickness of
7 mm:
Wall thickness
(mm)
Adapter type
Screw length
(mm)
Order kit
0 to 3.5
-
40
-
above 3.5 to 7
Washer 3.5
40
-
above 7 to 11.5
Washer 7
50
1
above 11.5 to 14
C
50
1
above 14 to 17.5
D
50
1
above 17.5 to 21
E
60
2
above 21 to 24
F
60
2
above 24 to 27
G
60
2
Содержание BADU BADUJET Turbo Pro
Страница 1: ...EN EN Translation of original operation manual Submerged counter swim unit ...
Страница 20: ...Installation 20 EN 08 2020 Pool cutout for concrete pools formwork Fig 4 ...
Страница 21: ...Installation 08 2020 EN 21 Installation of formwork for concrete pools Fig 5 ...
Страница 34: ...Installation 34 EN 08 2020 5 4 4 Control cable wiring diagram Fig 18 ...
Страница 38: ...Installation 38 EN 08 2020 5 4 7 On off board circuit diagram Fig 20 5 4 8 Terminal box connections Fig 21 ...
Страница 49: ...Technical Data 08 2020 EN 49 10 2 Exploded drawing Fig 26 ...