7.3.1.2 Cleaning the dividing chamber and secondary piston (ref. 3 Fig. 14 on
page 55)
To clean the secondary piston (
ref. 3
Fig. 13
) proceed as follows:
- check through the cover door (
ref. 11 Fig. 4
on page 23) that the safety pin (
ref.
4 Fig. 13
) is placed completely outside the shoulder in order to pull it out; if it does
not happen operate by impulses on the start and stop button until it will be pos-
sible to extract it.
- remove the guard (
ref. 11
Fig. 4
);
- raise the block (
ref. 5
Fig. 13
) by rotating it around the pin (
ref. 6
Fig. 13
);
- remove the piston (
ref. 3
Fig. 13
);
- clean thoroughly the piston (
ref. 3
Fig. 13
);
- also clean the chamber in which it is housed;
- reinsert the piston (
ref. 3
Fig. 13
);
- lower the block (
ref. 5
Fig. 13
);
- insert the plug (
ref. 4
Fig. 13
);
- refit the guards.
7.4
Routine maintenance
The routine maintenance operations described in this manual are
performed by
the Customer
.
7.4.1
Mechanical maintenance
7.4.1.1 Tension of belts:
not applicable to this machine.
Prohibition!
Do not attempt to clean the dividing chamber using any procedure other
than the one described above; in particular, do not access the chamber
from the top of the hopper by standing on steps or other support surfaces;
this applies even if the machine is switched off, because accidental start-
up of the machine, no matter how unlikely, may result in serious personal
injury.