- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
136
Table 10.7-19 ATWGSFT1 / ATWRSFT1 / ATWBSFT1 / ATWMSFT1
ATWGSFT 1 / ATWRSFT1 /
ATWBSFT1 / ATWMSFT1
ATW Green ShiFT1 / ATW Red ShiFT1
ATW Blue ShiFT1 / ATW Magenta ShiFT1
Category
CAT15_Byte8,9,10,11_bit0-7 (8 bits each)
Outline
ATW convergence point shift 1
Sets the convergence range frame in the G, R, B and Mg directions.
Conditions AWBSFT=0[h]
Available settings range
0[h]-FF[h] 8bit
Initial value
2[h]/ 2[h]/ 2[h]/ 2[h]
Description
When AWBSFT is "0[h]" (Auto discrimination mode), the G, R, B and
Mg convergence points can be shifted in an optional direction.
Notes
When this value is too large, convergence operation is not performed.
This parameter is only valid in ATW mode.
Table 10.7-20 ATWRSFT2 / ATWBSFT2
ATWRSFT2 / ATWBSFT2
ATW Red ShiFT2 / ATW Blue ShiFT2
Category
CAT15_Byte8,9,10,11_bit0-7 (8 bits each)
Outline
ATW convergence point shift 2
Sets the shift amount in the R and B directions.
Conditions AWBSFT=1[h]
Available settings range
0[h]-FF[h] 8bit
Initial value
2[h]/2[h]
Description
When AWBSFT is "1[h]" (Select 1 point mode), a single point can be
selected as the convergence point.
Notes
When this value is too large, convergence operation is not performed.
This parameter is only valid in ATW mode.