- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
92
Table 10.2-8 VH Aperture Compensation Related Parameters
Parameter name
Description
Initial value
VHAPG
CAT2
Byte4_bit2-5
Sets the gain after adding V and H aperture
compensation.
from x0(0[h]) to x2(F[h])
6
VHAPSL
CAT2
Byte5_bit0-3
Applies slice after adding V and H aperture
compensation
4
Table 10.2-9 Highlight Aperture Compensation Related Parameters
Parameter name
Description
Initial value
HLAPG
CAT2
Byte4_bit6-7
Highlight aperture compensation total gain setting
from x0(0[h]) to x2(3[h])
2
HLAPTHLV
CAT2
Byte5_bit4-5
Sets the threshold level of adding highlight
aperture compensation.
0:>50% 1:>37.5% 2:>25% 3:>12.5%
3
HLAPPG
CAT2
Byte5_bit6-7
Highlight aperture compensation gain +side setting
from x0(0[h]) to x1(3[h])
3
HLAPMG
CAT2
Byte6_bit0-1
Highlight aperture compensation gain –side setting
from x0(0[h]) to x1(3[h])
3
HLAPDS
CAT2
Byte6_bit2
Switches the highlight aperture compensation
detection point.
0: Before gamma 1: After gamma
0
HLAPSL
CAT2
Byte6_bit3-6
Applies slice to highlight aperture compensation.
4