- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
161
Blemish correction count setting
The maximum number of detected blemishes is always 32. However, the number of corrections is set using
the following parameter.
Table 11.2-8 Parameter for setting the number of blemish corrections
Parameter
Description
DEFNUM CAT11_Byte3_bit2-6
Correction count setting
0[h]:1 correction - 1F[h]:32 corrections
* These parameters can be used for both static detection and dynamic detection.
Accumulation time setting
This parameter sets the accumulation time (number of accumulated frames) for static detection. For low-level
blemishes, the blemish level will gradually increase as the accumulation time is increased.
When the blemish level exceeds the set threshold level, a blemish is recognized and detected.
Table 11.2-9 Parameter for setting accumulation time
Parameter
Description
DETACCT
CAT11_Byte12_bit2-7
Number of fields accumulated
(only non-zero even numbers can be set)