- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
249
13.3. Tables: The parameters controlled by FW
CAT1 SYSTEM
Byte, bit
Parameter
FW control timing
Control methods (Except CPUHOLD=1)
Byte1_bit0
NTPAL
Byte1_bit2
CCDTYPE
Byte3_bit0,1
ENCMODE
Reset
These parameters are controlled by MODESEL..
Please do not change parameters controlled by FW.
Byte3_bit4-5
TGCKSEL
Every field
These parameters are controlled by SGMODE..
Please do not change parameters controlled by FW.
Byte3_6-7
INTLCKSEL
Byte4_6-7
DIFCKSEL
Reset
These parameters are controlled by MODESEL..
Please do not change parameters controlled by FW.
Byte7_bit6 S0IN
Byte7_bit7 S1IN
Byte8_bit0-2 S2SEL
Byte8_bit3-5 S3SEL
Byte8_bit6,7 S4SEL
SGHOLD(CAT12_Byte5_bit4)=1[h]
or
SSELOFF(CAT12_Byte12_bit5)=1[h]
Byte11_bit1 PLLSTB
Every field
SGHOLD(CAT12_Byte5_bit4)=1[h]
Byte12_bit2
YDACCKSEL
Every field
These parameters are controlled by SGMODE..
Please do not change parameters controlled by FW.
CAT2 PICT1
Byte, bit
Parameter
FW control timing
Control methods (Except CPUHOLD=1)
Byte4_bit2-5 VHAPG
VHAPGCTL(CAT12_Byte8_bit0)=1[h]
Byte6_bit7 YGAMSON
Byte7_bit0 YGAMSLV
Byte7_bit1 YGAMSMTH
Byte7_bit2-4 YGAMSEL
Byte7_bit5-7 YKNEESEL
GAMCTL(CAT12_Byte9_bit0)=1[h]
Byte8 YGAIN
YGAINCTL(CAT12_Byte8_bit3)=1[h]
Byte10_bit0-5 SETUP
SETUPCTL(CAT12_Byte8_bit7)=1[h]
Byte11_bit1-4 YDLY
YDLYOFF(CAT12_Byte13_bit0)=1[h]
Byte29_bit6 CKNEE2
Byte30_bit0-2 CGAMMA
Byte30_bit3,4 CKNCLIP
Byte30_bit5-7 CKNEE
GAMCTL(CAT12_Byte9_bit0)=1[h]
Byte31 RMATY
Byte32 RMATC
Byte33 BMATY
Byte34 BMATC
Byte35 GMATCR
Byte36 GMATCB
RGBMATCTL(CAT12_Byte8_bit1)=1[h]
Byte37 RYGAIN1
Byte38 BYGAIN1
CRGAINCTL(CAT12_Byte8_bit2)=1[h]
Byte39 RYHUE1
Byte40 BYHUE1
HUECTL(CAT12_Byte8_bit4)=1[h]
Byte41 RYGAIN2
Byte42 BYGAIN2
CRGAINCTL(CAT12_Byte8_bit2)=1[h]
Byte43 RYHUE2
Byte44 BYHUE2
HUECTL(CAT12_Byte8_bit4)=1[h]
Byte45 RYGAIN3
Byte46 BYGAIN3
CRGAINCTL(CAT12_Byte8_bit2)=1[h]
Byte47 RYHUE3
Byte48 BYHUE3
Every field
HUECTL(CAT12_Byte8_bit4)=1[h]