- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
31
4. Parameter Configuration
4.1. Communication Parameter Concept
4.1.1. Communication Category Concept
The communication parameters for SS-HQ1 are divided into the 24 categories shown below.
Communication categories are divided into separate segments for each control target, so that the byte
positions of the individual parameters are easy to remember.
4.1.2. Communication Category Details
Table 4.1-1 Serial Communication Classification Table
Category number
Category name
Description
CAT1 SYSCON
Parameters
related
to general setting of system
CAT2
PICT1
Image quality setting parameters 1
CAT3
AE1
Parameters related to AE 1
CAT4
AWB1
Parameters related to AWB 1
CAT5
OPDWIND1
Parameters related to OPD window 1
CAT6
TG
Parameters related to TG
CAT7
EXTSYNC1
Parameters related to external synchronization 1
CAT8 FEADJ(EVRI)
Parameters related to built-in EVR
CAT9
MASKPG
Parameters related to mask function and PG
CAT10
DIF
Parameters related to digital interface
CAT11
BLMDETS1
Parameters related to blemish detection and compensation 1
CAT12
CPU
Built-in controller setting and operation mode setting
CAT13
PICT2
Image quality setting parameters2
CAT14
AE2
Parameters related to AE 2
CAT15
AWB2
Parameters related to AWB 2
CAT16
OPDWIND2
Parameters related to OPD window 2
CAT17
EXTSYNC2
Parameters related to external synchronization 2
CAT18 FEADJ(EVREXT) Parameters related to external EVR
CAT19
PREADJ
Parameters related to line adjustment
CAT20
PORT
Port driver setting parameters
CAT21
BLMDET2
Parameters related to blemish detection and compensation 2
CAT22
SOUT1
Serial output setting parameters 1
CAT23
SOUT2
Serial output setting parameters 2
CAT24
TEST
Parameters related to LSI
CAT24 (TEST) is an undisclosed parameter for testing purpose.
CAT20 is a port driver control setting parameter, while CAT12-19, CAT-22, and CAT-23 are firmware control
parameters of the built-in CPU.
CAT1-11 are hardware parameters. Note however, that care is necessary because even if the values of
parameters for controlling port drivers (CAT20) and firmware (CAT12-19) are set directly by external
communication, they will be overwritten by port drivers or the firmware. To directly control these parameters for
control using external microcomputer and so on, port driver controls are required to be reset and firmware to be
stopped (HOLD processing).
(For details of list of parameters for firmware control and the setting method, refer to "13.3 Tables: The
parameters controlled by FW".)
Do not change MODESEL and SGMODE control parameters because they are controlled by firmware.