- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
119
Table 10.6-11 AEWAIT
AEWAIT
AE WAIT time
Category CAT14_Byte11_bit0-7
(8bit)
Outline
The hysteresis counter can be set.
Conditions
AEHYST>0, AEWAIT>0, AEHYST>AESTAB
Available settings range
00[h] to FF[h] 8bit
Initial value
0[h]
Description
The greater the value, the less responsive AE is with respect to
momentary fluctuations of the subject's luminance level. The smaller
the value, the more responsive the reaction.
Notes