- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
38
5.1.2. Parameters Exclusively for Initialization
Parameters in the following table are only valid during initialization operations. After the initialization, both
external communication and port driver control are disabled. To change this, the following procedure is
required:
(CPUHOLD) -> overwrite the EEPROM values -> XRST=L (reset again) -> read from EEPROM -> reinitialize
Table 5.1-1 Parameters Valid Only during Power-on Sequence (Initialization Operations)
CAT
Byte
Bit
Parameter
Initial settings
1 0-3
MODESEL
Loaded from P12-P15
(CAT20 setting)
10
0
BPSSEL
1 : RS-232C 19200bps
10
1
EVRLDSEL
0 : CSROM -> S4 out
13
1
SYSSELON
0 : OFF
13 2
SYSSELFLG
16 0-7
MODESEL0
17 0-7
MODESEL1
18 0-7
SGMODE0
19 0-7
SGMODE1
20 0-7
EVR20
12_CPU
21 0-7
EVR21
Disabled if SYSSELON = 0
4 0-7
GGAIN
&H26
15_AWB2
62 0-7
MASKCNT
&H07
20_PORT
1-48
0-7
(all parameters)
See the port driver chapter