- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
137
Dead band adjustment
Table 10.7-21 WBDBAND
WBDBAND
White Balance DeadBAND
Category CAT15_Byte14_bit0-7
(8bit)
Outline
Sets the dead band width for the convergence point complete judgment.
Conditions
Available settings range
0[h]-FF[h] 8bit
Initial value
10[h]
Description
Setting a large WBDBAND value is effective for stabilizing operation.
Notes
Table 10.7-22 DBANDR / DBANDB / DBANDM / DBANDG
DBANDR / DBANDB /
DBANDM / DBANDG
DeadBAND Red / DeadBAND Blue
/ DeadBAND Magenta / DeadBAND Green
Category
CAT15_Byte15,16,17,18_bit0-7 (8 bits each)
Outline
Sets the dead band width in the R, B, Mg and G directions for the
convergence start judgment.
Conditions
Available settings range
0[h]-FF[h] 8bit
Initial value
12[h]/ 12[h]/ 12[h]/ 12[h]
Description
The dead band can be adjusted in the four directions of R, B, Mg and G.
These parameters are the dead band widths used to make the next
convergence start judgment after convergence has been performed. The
dead band width can be set in four directions, which makes it difficult for
convergence operation to start even when the color changes in that
direction.
Notes
Fig 10.7-3 Dead band of ATW
DBANDR
DBANDM
DBANDB
DBANDG
(R-B)/G
(R+B-2G)/G
WBDBAND