6.
Remove the AXM-52 board.
1) Disconnect the flexible flat cable from the connector (CN106) on the AXM-52 board.
2) Disconnect the harness from the connector (CN107) on the AXM-52 board.
3) Remove the protection sheet (AXM).
4) Remove the two drop protection cushions and the two slide SW knobs from the two switches on the AXM-52
board.
Drop protection cushion
Drop protection cushion
Slide SW knob
Switches
Harness
Flexible flat cable
Slide SW knob
AXM-52 board
CN106
CN107
Protection sheet (AXM)
7.
Install the removed parts by reversing the steps of removal.