Chapter 11 System Configuration
11-23
Chapter 11
Switch settings
PCM-3348HR settings
Switch
Master unit
Slave unit
REC MODE
INSERT
INSERT
SYNC CLOCK
VIDEO
Set automatically
Fs
Set automatically
Set the same as
the master unit
REFERENCE
When terminated: ON
VIDEO INPUT
For loop-through
—
75
Ω
output: OFF
TIME CODE
EXT
—
selection
TIME CODE GEN Format being used
—
format selection
RM-3348HR settings
Switch
Master unit
Slave unit
SELECTOR
ON (MASTER)
OFF (SLAVE)
switch No.2 (lower)
SELECTOR switch No.4: OFF
No.4: OFF
No.4 to 8 (lower)
No.5: OFF
No.5: OFF
No.6: OFF
No.6: OFF
No.7: OFF
No.7: OFF
No.8: OFF
No.8: ON
Device address:
Device address:
00H
01H
SLAVE button
OFF
ON
Timer display mode CTL ABSOLUTE
CTL ABSOLUTE
or CTL RELATIVE or CTL RELATIVE
Notes on operation
•
The master PCM-3348HR, the video equipment, and
the time code synchronizer are all synchronized to a
composite video signal.
•
The slave PCM-3348HR is synchronized to the
master unit by the word sync signal. The two PCM-
3348HR units must therefore have the same sampling
frequency.
•
Use cables with BNC connectors to connect the word
sync, sector sync and sector address signals.
•
By setting the VARI SYNC switch on the MC board
of the master PCM-3348HR unit to ON, you can use
the variable speed playback function to control the
tape transport on both the master
and slave units.
•
Use a prestriped tape and carry out insert recording.
•
The tape on the slave unit must be prestriped with the
same sampling frequency as the master unit.
Содержание PCM-3348HR
Страница 8: ...1 2 Chapter 1 Overview Chapter 1 ...
Страница 86: ...4 32 Chapter 4 Basic Operations of the RM 3348HR Remote Control Unit Chapter 4 ...
Страница 114: ...5 28 Chapter 5 Time Shift Editing Using the Sound Memory Chapter 5 ...
Страница 126: ...6 12 Chapter 6 Digital Copy Chapter 6 ...
Страница 142: ...7 16 Chapter 7 Synchronized Operations Chapter 7 ...
Страница 172: ...10 16 Chapter 10 External Synchronization Chapter 10 ...