Chapter 10 External Synchronization
10-9
Chapter 10
Example synchronization signal
connections (3)
This example illustrates signal connections for using
an AES/EBU format synchronization signal for
synchronization.
Example configuration (3) for external synchronization of
a PCM-3348HR and a PCM-9000
Notes on system configuration
•
In this configuration the slave and master units must
have the same sampling frequency. You can use 48.0
kHz, 44.1 kHz, 44.056 kHz as the sampling
frequency.
•
Set the SYNC CLOCK switch to INT on the master
PCM-3348HR unit, and to DI on the slave unit.
TAPE
RECORDER
REMOTE-3
AES/EBU
D-I
AES/EBU
D-O
AES/EBU
D-O
AES/EBU
D-I
Master (or slave)
unit
PCM-9000
Slave (or
master) unit
AES/EBU format
digital audio signals
RM-3348HR
INPUT SELECT
switch: 2CH DI
SYNC CLOCK
switch: INT (or
DI)
PCM-3348HR