Chapter 3 Basic Operations
3-19
Chapter 3
LOCK
TCR
TC SYNC PLAY
OFF
ON
CHASE MODE
FREE
ADRS
PB REGENE
OFF
ON
MC board
MC board
1
SELECT switch No. 4 (VARI SYNC)
This selects whether the vari sync function is on or off
during time code sync playback.
When this switch is off, the sector sync function is
enabled.
2
TC GEN (time code generator) switch
Select the advancement mode for the time code.
REC RUN: The time code only advances while the
PCM-3348HR is actually recording.
FREE RUN: As long as the PCM-3348HR is powered
up, the time code advances irrespective of whether
or not it is recording.
3
OUTPUT switch
Select the output timing for the time code.
NORM: The time code is output at the in-line point.
ADV: The time code is output ahead of the in-line point.
4
PB TC (playback time code) GAIN switch
NORM: For normal use (factory-set position).
LOW: For playback of time codes recorded on the PCM-
3324A/3324.
In addition, you can turn the phase correction function
of the internal time code generator on and off with an
internal switch.
For internal settings of the board, see “MC board” (page A-
20) in Appendixes, “Location and Function of Parts.”
TCR Board
TCR board
1
PB REGENE (playback time code regeneration)
LOCK lamp
This lights when a playback time code is input and is
being correctly regenerated. If the playback time code
ceases to be input, this lamp goes off even if
regeneration continues.
2
PB REGENE (playback time code regeneration)
switch
Select whether or not to regenerate the playback time
code.
ON: Regenerate the playback time code, and output it
from the TIME CODE OUTPUT connector.
OFF: Output the playback time code unaltered from
the TIME CODE OUTPUT connector.
3
TC (time code) SYNC PLAY switch
This enables or disables time code sync playback.
When using time code sync playback, use SELECT
switch No. 4 (VARI SYNC) on the MC board to set
the vari sync function on or off.
In addition, you can turn the time code interpolation
function in fast-forward and rewind modes on and off
and select the frame frequency for this function with
the internal switches.
For internal settings of the board, see “TCR board” (page
A-21) in Appendixes, “Location and Function of Parts.”
1
OFF
12
3
4
ON
OUTPUT
TC GEN
TIME CODE
TEST
MC
NORM
ADV
PB TC GAIN
NORM
LOW
REC
RUN
FREE
RUN
SELECT
BACK UP
2
AUTO REC
3
D10.NO.DLY
4
VARI SYNC
1
SELECT switch No. 4 (VARI SYNC)
2
TC GEN switch
3
OUTPUT switch
4
PB TC GAIN switch
1
PB REGENE LOCK lamp
2
PB REGENE switch
3
TC SYNC PLAY switch
Содержание PCM-3348HR
Страница 8: ...1 2 Chapter 1 Overview Chapter 1 ...
Страница 86: ...4 32 Chapter 4 Basic Operations of the RM 3348HR Remote Control Unit Chapter 4 ...
Страница 114: ...5 28 Chapter 5 Time Shift Editing Using the Sound Memory Chapter 5 ...
Страница 126: ...6 12 Chapter 6 Digital Copy Chapter 6 ...
Страница 142: ...7 16 Chapter 7 Synchronized Operations Chapter 7 ...
Страница 172: ...10 16 Chapter 10 External Synchronization Chapter 10 ...